Equipment of medium voltage – Switchgear and Substation

With a tradition of 26 years, we have managed to maintain, be an indispensable partner and competitive in the market in the design, engineering, sales and distribution of equipment .

As a new step in development, Kopring-Em starts distributing and offering switchgear , the renowned company EFACEC, one of the world leaders in the field of electric power solution based in Portugal. In its product range the company EFACEC on medium voltage switchgear has offered switchgear for primary and secondary distrubtion. Air and SF6 insulated switchgears are offered with vacuum circuit breakers withdrawable and fixed performanceIn addition, they have oil and dry distribution transformers in their production facilities as well as a complete range of microprocessor protection devices for the protection of medium and high voltage switchgear, as well as its product portfolio system automation and SCADA system.

Switchgear equipment substation ; 110kV – 35kV – 20kV – 10kV

1. Switchgear according to IEC 62271-200 standard with indoor and outdoor installation with complete certificates of accredited independent laboratories

Characteristics of cubicles:

– nominal voltage of 12kV, 17.5kV, 24kV i 36kV
rated short circuit currents up to 25kA do 50kA
– rated bus voltage from 630A to 4000A                                                                                                                                – degree of protection IP4X; IP41                                                                           

Primary distribution                                                                                                                                                                                                 36kV – QBN7 – Withdrawable Metal-clad Switchgears,                                                                                                    The construction of QBN7 switchgear is internal arc resistant in accordance with IEC 62271-200, PM type, A FLR accessibility, for the protection of personnel and other equipment, rated short-time current 31.5kA                                12kV and 17.5kV 24kV – NORMACEL – Withdrawable Metal-clad Switchgears,                                                                    Single and double busbar system, the construction of NORMACEL switchgear is internal arc resistant in accordance with IEC 62271-200, PM type, AFLR accessibility, for the protection of personnel and other equipment, rated short-time current 50kA

Secondary distribution

NORMAFIX – Modular air-insulated switchgear:                                                                                                             12kV, 17.5kV, 24kV, 36kV Rated voltage                                                                                                                                Rated current up to 630A / 1250A                                                                                                                               Degree of insulation from 28kV to 70kV                                                                                                                         Short circuit currents from 16kA (3s) to 25kA (1s)

FLUOFIX GCModular SF6 insulated switchgear:
12kV, 17.5kV, 24kV, 36kV Rated voltage
Rated current up to 630A
Degree of insulation  28kV/ 75kV;  38/95 kV50/125 kV; 70/170 kV
Short circuit current 16kA(3s) to 20kA (1s)

RMU SF6 (Ring Main Units) – SF6 insulated switchgear :
12kV,17.5kV, 24kV (do 630A , 20kA 1s)

Configuration:                                                                                                                                                                     2IS+CIS;  2IS+DC ;
2IS+SBM ; 3IS+2CIS ;
and configurations that were requested by the client

2. Three-phase Oil distributive transformers range of power from 50kVA to 2500kVA, manufactured according to IEC standard 60076.                                                                                                                                                   Nominal voltage: High voltage side up to 36kV, with regulation ± 2×2.5%.                                                                 Lower voltage   400V, 420V                                                                                                                                              Vectors group  Dyn5 or Dyn11

3. Three-phase Dry distributive trasformers range of power from 250kVA to 2500kVA, manufactured according to IEC standard 60076.

Nominal voltage: High voltage side up to 36kV, with regulaton ± 2×2,5%
Lower voltage 400V, 420V
Vectors group  Dyn5

4. Disconnectors

Air-insulated type ISP and ISPF rated voltages 12kV, 17.5kV, 24kV and 36kV.                                                                    Rated currents up to 400A, short-circuit breaking currents from 12.5kA to 16kA (3s)

Switch disconnector SF6 ( load disconnector) mounted on the pillar
Designed for manual and electrical manipulation
12 kV, 17.5kV, 24kV, 36kV
400A to 630A
12.5kA to 16kA (3s)
-25 ºC/+40 ºC
IP54, IP67

5. Compact Concrete and Metal enclosed substation:

Medium voltage part up to 35kV, low voltage part up to 1000V,                                                                                   With transformers up to 35kV, power up to 1600kVA .

Dimensions of compact concrete Substation:                                                                                                                   Width 3500mm to 8500mm, Depth 2520mm, Height 2600mm

Dimensions of compact metals Substation:
Width 3350mm to 5600mm, Depth 1600mm to 2250mm, Height 1930mm to 2335mm

 

12

Kopring-EM,
with more than 28 years experience in business, provides high quality and professional services to all his clients.

 

Contact

Kopring-EM DOO
Address
Ulcinjska 10
18000 Niš

Phone:
+381 64 212 1573
+381 62 200 149

E-MAIL:
kopring@kopring.rs

 

Contact

Kopring-EM DOO
21000 Novi Sad

Phone:
+381 64 119  7136

E-MAIL:
kopring@kopring.rs